INSTALLED HEATING - PANEL HEATERS

EVS range

Controls for ancillary appliances RXPWIF pilot wire interface unit

The RXPWIF pilot wire interface unit provides additional system versatility by allowing ancillary appliances, such as towel rails or water heaters, to be controlled via a pilot wire programmer (typically RXPW4 4-zone controller).

  • Allows control over ancillary appliances up to 3kW (16A) load (typically towel rail or hot water cylinder immersion heater).
  • Installed local to the appliance being controlled. 38mm single gang wiring accessory back box required (not supplied).
  • Switches power to appliance when programmer in comfort mode; disconnects supply when programmer in all other modes.
  • Ideal for use with RXPW4 4-zone pilot wire programmer.

Pilot wire connection

Pilot wire installations utilise an additional control wire linked between each heater. This is a 240V live conductor, carrying a low current signal to activate the various modes on the heater electronic control. Up to 20 heaters per zone can be supported (dependent on controller and application).

This system is ideal for new build applications as the pilot wire can be installed with the first fix wiring. As heaters require no additional receivers, this offers a cost-effective means of central control.

Four Zone Configuration

Name and Registered Office: Dimplex (UK) Limited, Millbrook House, Grange Drive, Hedge End, Southampton, Hants, SO30 2DF, United Kingdom.