KITCHENS AND BATHROOMS - TOWEL RAILS

BR range

Technical Specification

Controls

No external controls. Built-in temperature limiter and overheat protection. Suitable for connection to external thermostats or timers, in

accordance with IEE regulations.

Finish

White powder coated or chrome plated.

Construction

Sealed, liquid filled steel shell. Water based fluid with glycol frost/corrosion inhibitor. Vertical mounted immersion element.

IP Rating

Splash-proof IPX4 for bathroom use.

Installation

Supplied with wall mounting points and brackets.

Electrical Connection

1 metre of electrical cable pre-fitted. Cable entry at base of left header tube. Installations must be in accordance with current IEE wiring regulations.

Installation to Radiator Circuit

Installation must be in accordance with manufacturer's instructions. Liquid is drained by removing bungs to inlet/outlet connections (1/2" BSP fittings). Connect to radiator circuit (electric element remains in situ). Radiator refilled from radiator circuit and bled using valve concealed below top right header cap. Electrical connection as electric only installation.

Operation when part of Radiator Circuit

When the central heating system is in use the appliance will act as a normal radiator. Out of season or when the boiler is not in use the radiator may be operated independently by switching on the electric element. In use expansion of water must be guaranteed through return connection. Return connection should be left open to ensure this.

Model No. BR150W BR150C BR200C BR250 BR350C BR400 BR500
No. of Rails 10 10 10 10 16 16 22
Output (Electric)* 150W 150W 200W 250W 350W 400W 500W
Approx Output (Water)* 320W 320W 475W 525W 750W 840W 1050W
Height (A) 665mm 665mm 665mm 665mm 1003mm 1003mm 1345mm
Width (B) 430mm 430mm 630mm 630mm 630mm 630mm 630mm
C 385mm 385mm 603mm 447mm 603mm 447mm 447mm
Depth (D) 155mm 155mm 155mm 155mm 155mm 155mm 155mm
E 268mm 268mm 268mm 268mm 268mm 268mm 268mm
Finish White Chrome Chrome White Chrome White White
Weight 6.5kg 6.5kg 8kg 9kg 13kg 15kg 20kg

 * For BTU output multiply by 3.412

Name and Registered Office: Dimplex (UK) Limited, Millbrook House, Grange Drive, Hedge End, Southampton, Hants, SO30 2DF, United Kingdom.
Company No.1313016 EEE Producer Registration Number – WEE/GE0057TS