KITCHENS AND BATHROOMS - UNDERTILE

under-tile heating

Technical Specification

Construction

• Twin Core 160W/m2 cable.

• Fully screened for use in bathrooms or other wet areas.

• Two layers of insulation for maximum cable life.

• Easy to cut mesh backing that can be removed for small and awkward areas.

Electrical

• All installations should be carried out by a qualified electrician in accordance with the current wiring regulations.

• All installations require an RCD (residual current device) for safe operation.

• The Dimplex thermostatic controller has maximum load of 15A.

• Connecting more than two mats to a controller requires the use of a standard electrical junction box.

• The Dimplex thermostatic controller comes complete with a floor sensing probe.

Installation Guidelines

The Dimplex under-tile heater can be fitted to:

• Timber suspended floors.

• Concrete solid floors.

• Dimplex strongly recommends the use of 10mm insulating tile backer board to maximise system performance.

Design Freedom

By being concealed under the tiled floor, under-tile heating frees you to plan rooms and arrange furniture as you want, allowing a great deal of flexibility.

Flexible Control

Because Dimplex under-tile heating is controlled independently of the main heating system, it offers maximum flexibility. Separate settings can be programmed whether you are in, out or even on holiday, and the early start function always ensures the floor has reached your chosen temperature when you want it.

Safety and Practicality

A warm tiled floor helps spills to dry quickly, avoiding slip-ups in bathrooms and kitchens, promoting a safer environment for all the family.

Mat Dimensions and Loadings

Model No Output 230V Area ElementDepth WidthA Length B
DTW1M 160W 1.0m2 3mm 500mm 2000mm
DTW1.5M 195W 1.5m2 3mm 500mm 3000mm
DTW2M 260W 2.0m2 3mm 500mm 4000mm
DTW3M 390W 3.0m2 3mm 500mm 6000mm
DTW4M 520W 4.0m2 3mm 500mm 8000mm
DTW5M 650W 5.0m2 3mm 500mm 10000mm
DTW6M 780W 6.0m2 3mm 500mm 12000mm

Note: Each Mat comes with adhesive roll and instruction for installation.

Controller Dimensions and Loadings

Model No. Electrical Rating Accuracy Width A Height B Depth C Total Depth D
DTW16S 15A 0.5°C 79mm 83mm 22mm 44mm

Note: Always use a standard electrical junction box when connecting more than two mats.

Sizing Guide

Floor Length
Floor Width1m1.5m2m3m4m5m
1m 1 x DTW1M 1 x DTW1.5M 1 x DTW2M 1 x DTW3M 1 x DTW4M 1 x DTW5M
1.5m 1 x DTW1.5M 1 x DTW2M 1 x DTW3M 1 x DTW4M 1 x DTW6M 1 x DTW6M+1 x DTW1.5M
2m 1 x DTW2M 1 x DTW3M 1 x DTW4M 1 x DTW6M 2 x DTW4M 2 x DTW5M
3m 1 x DTW3M 1 x DTW4M 1 x DTW6M 3 x DTW3M 2 x DTW6M 3 x DTW5M
4m 1 x DTW4M 1 x DTW6M 2 x DTW4M 2 x DTW6M 4 x DTW4M 4 x DTW5M
5m 1 x DTW5M 1 x DTW6M + 1 x DTW1.5M 2 x DTW5M 3 x DTW5M 4 x DTW5M 5 x DTW5M


Note: Always choose heater packs that are slightly smaller than your requirement as only the mesh can be cut. (Not the wire!) This chart is for illustrative purposes only. Do not place under-tile heating under permanent fixtures (e.g. baths, kitchen cupboards)