T Range
Technical Specification
Controls
No controls supplied. However, heaters are very suitable for connecting to a time-switch or thermostat.
IP Rating
IPX4.
Safety
An auto-reset safety cut-out is incorporated in the heater to prevent damage due to over-heating. The appliance is fully splashproofed.
Fixing
Discreet wall/floor mounting brackets are provided. Horizontal mounting only.
Installation
Supplied with 1.5M cable and fitted plug. When connecting to fixed wiring, a suitable double pole isolating switch should be provided adjacent to the heater. The clearances shown must be maintained. If the heater is not to be wall mounted, then it must be permanently fixed to the floor.
Interlinking Kit
Tubular linking kit (Part No: 85731506) available as optional extra. Kit enables 2 heaters to be banked vertically or stepped.
Colour/Finish
White body, grey ends and wall brackets.
| Model | Length | Height | Depth |
|---|---|---|---|
| T60W | 350mm | 81mm | 80mm |
| T120W | 655mm | 81mm | 80mm |
| T240W | 1265mm | 81mm | 80mm |
| T360W | 1875mm | 81mm | 80mm |


Name and Registered Office: Dimplex - a division of the GDC Group,
Millbrook House, Grange Drive, Hedge End, Southampton, Hants, SO30 2DF,
United Kingdom.
Company No.1313016
EEE Producer Registration Number WEE/GE0057TS
WEEE Distributor Take
Back Scheme - Registration ID: 6131