LAS MT range
Technical Specification

| Model number | LAS 10MT | LAS 15MT | |
| Dimensions (W x D x H)** | mm | 1270 x 670 x 860 | 1270 x 670 x 860 |
| Temperature operating limits for pool water flow / return flow |
up to 40oC / above 10oC |
up to 40oC / above 10oC | |
| Heat output / power consumption at A+20/W24* | kW/- | 12,10 / 2,90 | 16,60 / 3,50 |
| Heat output / power consumption at A+15/W24* | kW/- | 11,00 / 2,80 | 15,00 / 3,40 |
| Heat output / power consumption at A+10/W24* | kW/- | 10,10 / 2,70 | 13,50 / 3,30 |
| Sound power level | db(A) | 70 | 70 |
| Sound pressure level at a distance of 10 m (air outlet side) | db(A) | 45 | 45 |
| Pool water flow rate at an internal pressure differential of | m³/h / Pa | 1,6 / 7200 | 2,0 / 12000 |
| Refrigerant R407C | kg | 1,50 | 1,60 |
| Weight (incl. packing) | kg | 147 | 155 |
| Electrical nominal power consumption at A15/W32 | kW | 3.30 | 4,00 |
| Control voltage | V | 230 | 230 |
| Supply voltage | 1/N/PE~230V, 50Hz | 1/N/PE~230V, 50Hz | |
| Starting current with soft start | A | 33 | 43 |
| Fuse | A | 20 | 25 |
| Nominal current at A+15/W32 | A | 17,0 | 17,0 |
| Defrosting / type of defrosting | A / -- | Electrical | Electrical |
* The specified values have the following meaning, e.g A20/W24: heat source temperature 20 °C, heat outlet temperature 24 °C. ** Please note that additional space is required for pipe connections, operation and maintenance.
Name and Registered Office: Dimplex - a division of the GDC Group,
Millbrook House, Grange Drive, Hedge End, Southampton, Hants, SO30 2DF,
United Kingdom.
Company No.1313016
EEE Producer Registration Number WEE/GE0057TS
WEEE Distributor Take
Back Scheme - Registration ID: 6131
This is an official website of
GDC Group Limited. The GDC Group manages the Dimplex brand.
Neither
the GDC Group nor Dimplex are associated with any other website
containing the Dimplex brand name