EC-Eau Heat Pump Cylinder Range

Specification

Materials
Inner Cylinder Duplex stainless steel
Cylinder Outer HIPS recycled materials
Coils Corrugated stainless steel
Insulation 60mm PU foam (GWP < 1, OPD = 0)

EC-Eau Heat Pump Cylinders

DIMENSIONS
ModelHeightDiameterT&P ValveSecondary returnHeat Pump returnHeat pump flowImmersionThermostat Weight empty (kg) Weight packaged (kg)
ECS150HP-580 1130 580 900 - 190 845 208 545 35 45
ECS210HP-580 1505 580 1275 967 190 895 208 732 42 53
ECS250HP-580 1780 580 1550 1105 190 895 208 870 47 60
ECS300HP-580 2080 580 1850 1255 190 930 208 1020 53 57

Measurements in mm, made from the bottom of the cylinder to the centre of the component

PERFORMANCE
ModelCapacity (litres)Primary hot water capacity (litres)Heat pump coil heatable volume (litres)Number of immersionsExpansion vessel (l)Coil size (kW)Coil surface area (m2)Reheat (mins)Max. standing heat loss  (kW/24hr)
ECS150HP-580 150 120(*) 141.5 1 12 51(*) 2.8 7(*) 1.10
ECS210HP-580 210 180(*) 210 1 19 47(*) 3.0 12(*) 1.41
ECS250HP-580 250 238(*) 250 1 24 47(*) 3.0 17(*) 1.51
ECS300HP-580 300 267(*) 300 1 24 43(*) 3.2 20(*) 1.96

(*) Determined in accordance with EN12897-2006

EC-Eau Heat Pump Cylinders with Buffer

DIMENSIONS
ModelHeightDiameterT&P ValveSecondary returnHeat Pump returnHeat Pump flowBuffer returnBuffer flowBuffer immersionImmersionThermostat Weight empty (kg) Weight packaged (kg)
ECS150HP75-580 1705 580 900 - 190 845 1268 1478 1293 208 545 49 60
ECS210HP75-580 2080 580 1275 967 190 895 1642 1852 1667 208 732 57 61

Measurements in mm, made from the bottom of the cylinder to the centre of the component

PERFORMANCE
ModelCapacity (l)Primary hot water capacity (l) Heat pump coil heatable volume (l)Buffer capacity (l)Number of immersionsExpansion vessel (l)Coils size (kW)Coil surface area (m2)Reheat (mins)Heat loss in 24hrs (kW/24hr)
ECS150HP75-580 150 120(*) 141.5 72 2 12 51(*) 2.8 7(*) 1.10
ECS210HP75-580 210 189(*) 210 72 2 19 47(*) 3.0 12(*) 1.41

(*) Determined in accordance with EN12897-2006

Name and Registered Office: Dimplex - a division of the GDC Group, Millbrook House, Grange Drive, Hedge End, Southampton, Hants, SO30 2DF, United Kingdom.
Company No.1313016 EEE Producer Registration Number WEE/GE0057TS
WEEE Distributor Take Back Scheme - Registration ID: 6131
This is an official website of GDC Group Limited. The GDC Group manages the Dimplex brand.
Neither the GDC Group nor Dimplex are associated with any other website containing the Dimplex brand name