RENEWABLE SOLUTIONS - AIR SOURCE - MEDIUM / HIGH TEMPERATURE

LA PS range

Technical Specification

Model number LA 11PS LA 17PS LA 22PS LA 26PS
Temperature operating limits for heating water / Air 65 °C / -25 °C 65 °C / -25 °C 65 °C / -20 °C 65 °C / -20 °C
Temperature operating limits for air -25 °C to 35 °C -25 °C to 35 °C -20 °C to 35 °C -20 °C to 35 °C
Heat output / COP at A-7/W35*kW/- 6,70 / 2,40 1 compressor:
6,70 / 2,50
2 compressors:
11,40 / 2,60
1 compressor:
7,70 / 2,40
2 compressors:
13,60 / 2,60
1 compressor:
8,70 / 2,40
2 compressors:
14,40 / 2,60
Heat output / COP at A+2/W35*kW/- 9,20 / 3,10 1 compressor:
8,70 / 3,20
2 compressors:
14,50 / 3,10
1 compressor:
10,60 / 3,00
2 compressors:
16,70 / 3,10
1 compressor:
11,70 / 3,00
2 compressors:
18,80 / 3,00
Heat output / COP at A+7/W35*kW/- 11,50 / 3,80 1 compressor:
10,10 / 3,60
2 compressors:
17,30 / 3,50
1 compressor:
12,60 / 3,80
2 compressors:
22,00 / 3,80
1 compressor:
13,70 / 3,60
2 compressors:
24,00 / 3,70
Heat output / COP at A+10/W35*kW/- 12,50 / 4,10 1 compressor:
12,00 / 4,30
2 compressors:
19,60 / 3,80
1 compressor:
13,70 / 4,20
2 compressors:
23,40 / 4,00
1 compressor:
15,00 / 4,10
2 compressors:
26,20 / 4,00
Electrical nominal power consumption at A+2/W35kW 2,98 4,74 5,00 6,20
Sound power leveldb(A) 64 64 68 68
Sound pressure level at a distance of 10 m (air outlet side)db(A) 34 37 41 41
Sound pressure level at a distance of 1 m (air outlet side)db(A) 58
Refrigerant R290kg 1,50 1,80 2,20 2,50
Flow rate (heat source)m³/h 4000 5500 8000 8000
Heating water flow rate with an int. pressure differential ofm³/h / Pa 1.1 / 2600 1.6 / 2900 2.0 / 4500 2.2 / 3100
Dimensions (W x D x H)**mm 1550 x 850 x 1570 1550 x 850 x 1570 1680 x 1000 x 1710 1680 x 1000 x 1710
Weight (incl. packing)kg 259 330 360 371
Control voltageV 230 230 230 230
Supply voltage 3/PE~400V, 50 Hz 3/PE~400V, 50 Hz 3/PE~400V, 50 Hz 3/PE~400V, 50 Hz
Starting current with soft starterA 30 23 25 30
FuseA 16 20 20 25
Defrosting / type of defrostingA / --
Device connections for heating 1" 1 1/4" 1 1/4" 1 1/4"

* The specified values have the following meaning, e.g. A+2/W35: heat source temperature +2 °C, heat outlet temperature 35 °C.
** Please note that additional space is required for pipe connections, operation and maintenance.


Name and Registered Office: Dimplex - a division of the GDC Group, Millbrook House, Grange Drive, Hedge End, Southampton, Hants, SO30 2DF, United Kingdom.
Company No.1313016 EEE Producer Registration Number WEE/GE0057TS
WEEE Distributor Take Back Scheme - Registration ID: 6131
This is an official website of GDC Group Limited. The GDC Group manages the Dimplex brand.
Neither the GDC Group nor Dimplex are associated with any other website containing the Dimplex brand name