RENEWABLE SOLUTIONS - AIR SOURCE - OUTDOOR

LA MS range

Technical Specification


Model number LA 11 MS LA 16 MS
Temperature operating limits for heating water / air 55 °C / -20 °C 55 °C / -20 °C
Temperature operating limits for air -20 °C to 35 °C -20 °C to 35 °C
Heat output / COP at A-7/W35* kW/- 7,60 / 2,90 9,80 / 2,60
Heat output / COP at A+2/W35* kW/- 9,10 / 3,40 12,70 / 3,20
Heat output / COP at A+7/W35* kW/- 10,90 / 4,10 15,40 / 3,70
Heat output / COP at A+10/W35* kW/- 12,00 / 4,60 16,10 / 3,80
Electrical nominal power consumption at A+2/W35 kW 2,65 3,95
Sound power level db(A) 63 64
Sound pressure level at a distance of 10 m (air outlet side) db(A) 33 34
Refrigerant R404A kg 2,50 3,10
Flow rate (heat source) m³/h 2500 4000
Heating water flow rate with an int. pressure differential of m³/h / Pa 1.0 / 3000 1.4 / 4500
Dimensions (W x D x H)** mm 1360 x 850 x 1360 1550 x 850 x 1570
Weight (incl. packing) kg 219 264
Control voltage V 230 230
Supply voltage 1/N/PE~230V, 50Hz 1/N/PE~230V, 50Hz
Starting current with soft starter A 38 50
Fuse A 25 32
Defrosting / type of defrosting A / -- Reverse cycle Reverse cycle
Device connections for heating 1" 1"

* The specified values have the following meaning, e.g. A+2/W35: heat source temperature +2 °C, heat outlet temperature 35 °C.
** Please note that additional space is required for pipe connections, operation and maintenance

Name and Registered Office: Dimplex (UK) Limited, Millbrook House, Grange Drive, Hedge End, Southampton, Hants, SO30 2DF, United Kingdom.
Company No.1313016 EEE Producer Registration Number – WEE/GE0057TS