RENEWABLE SOLUTIONS - AIR SOURCE - SWIMMING POOL HEATING

LAS MT range

Technical Specification


Model numberLAS 10MTLAS 15MT
Temperature operating limits for pool water flow / return flow up to 40oC
/ above 10o C
up to 40oC
/ above 10o C
Heat output / power consumption at A+20/W24* kW / kW 12,10 / 2,90 16,60 / 3,50
Heat output / power consumption at A+15/W24* kW / kW 11,00 / 2,80 15,00 / 3,40
Heat output / power consumption at A+10/W24* kW / kW 10,10 / 2,70 13,50 / 3,30
Sound power level db(A) 70 70
Sound pressure level at a distance of 10 m (air outlet side) db(A) 45 45
Pool water flow rate at an internal pressure differential of m³/h / Pa 1,6 / 7200 2,0 / 12000
Refrigerant R407C kg 1,50 1,60
Dimensions (W x D x H)** mm 1270 x 670 x 860 1270 * 670 * 860
Weight (incl. packing) kg 147 155
Electrical nominal power consumption at A15/W32 kW 3.30 4,00
Control voltage V 230 230
Supply voltage 1/N/PE~230V, 50Hz 1/N/PE~230V, 50Hz
Starting current with soft start A 33 43
Fuse A 20 25
Nominal current at A+15/W32 A 17,0 17,0
Defrosting / type of defrosting A / -- Electrical Electrical

* The specified values have the following meaning, e.g A20/W24: heat source temperature 20 °C, heat outlet temperature 24 °C. ** Please note that additional space is required for pipe connections, operation and maintenance.

Name and Registered Office: Dimplex (UK) Limited, Millbrook House, Grange Drive, Hedge End, Southampton, Hants, SO30 2DF, United Kingdom.
Company No.1313016 EEE Producer Registration Number – WEE/GE0057TS