RENEWABLE SOLUTIONS - AIR SOURCE - SWIMMING POOL HEATING
LAS TT range
Technical Specification

| Model number | LAS 22TT | |
| Temperature operating limits for pool water flow / return flow | to 10 °C / from 40 °C | |
| Heat output / power consumption at A+20/W24* | kW / kW | 22,30 / 4,40 |
| Heat output / power consumption at A+15/W24* | kW / kW | 20,30 / 4,30 |
| Heat output / power consumption at A+10/W24* | kW / kW | 18,10 / 4,20 |
| Sound power level | db(A) | 71 |
| Sound pressure level at a distance of 10 m (air outlet side) | db(A) | 46 |
| Pool water flow rate at an internal pressure differential of | m³/h / Pa | 2,5 / 8000 |
| Refrigerant R407C | kg | 2,50 |
| Dimensions (W x D x H)** | mm | 1270 x 670 x 860 |
| Weight (incl. packing) | kg | 162 |
| Electrical nominal power consumption at A15/W32 | kW | 5.10 |
| Control voltage | V | 230 |
| Supply voltage | 3/PE~400V, 50 Hz | |
| Starting current with soft starter | A | 25 |
| Fuse | A | 16 |
| Nominal current at A+15/W32 | A | 10,0 |
| Defrosting / type of defrosting | A / -- | Electrical |
* The specified values have the following meaning, e.g A20/W24: heat
source temperature 20 °C, heat outlet temperature 24 °C.
** Please note that additional space is required for pipe connections,
operation and maintenance.
Name and Registered Office: Dimplex (UK) Limited, Millbrook House,
Grange Drive, Hedge End, Southampton, Hants, SO30 2DF, United Kingdom.
Company
No.1313016
EEE Producer Registration Number – WEE/GE0057TS