EC-Eau Cylinders

Specifications

Indirect Solar Cylinders

DIMENSIONS
Model Height Diameter T&P Valve Solar Coil return Solar Coil flow Aux. Coil return Aux Coil flow Immersion Thermostat 1 Thermostat 2
ECSi175ST-580 1280 580 1050 190 525 740 995 580 330 847
ECSI210ST-580 1505 580 1275 190 525 837 1052 615 330 940
ECSi250ST-580 1780 580 1550 190 525 905 1120 640 330 1012
ECSi300ST-580 2080 580 1850 190 525 992 1207 640 330 1095

Measurements in mm, made from the bottom of the cylinder to the centre of the component

PERFORMANCE
Model Capacity (l) Aux. heated volume (l) Solar volume (l) Weight empty (kg) Weight full (kg) Aux Coil size(kW) Aux coil surface area (m2) Solar coil size (kW) Solar coil surface area (m2) Number of immersions Aux reheat (mins) Solar reheat (mins)
Heat loss in 24hrs (kW/24hr)
ECSi175ST-580 175 80(*) 95(*) 37 210(+) 20(*) 0.8 23(*) 1.1 1 12(*) 23(*) 1.3(y)
ECSi210ST-580 210 110(**) 100(**) 42(+) 252(+) 19(**) 0.8 22(**) 1.1 1 17(**) 23(**) 1.5(y)
ECSi250ST-580 250 150(**) 100(**) 46(+) 300(+) 19(**) 0.8 21(**) 1.1 1 27(**) 34(**) 1.7(y)
ECSi300ST-580 300 175(*) 125(*) 52 360(+) 18(*) 0.8 20(*) 1.1 1 31(*) 42(*) 1.9(y)


(*) Measured in accordance with EN12897-2006 at 80°C flow temperature and 0.25 l/s fl ow rate or operation of immersion heater.
(**) Calculated - based on measurements made in accordance with EN12897 at 80°C fl ow temperature and 0.25 l/s flow rate or operation of immersion heater.
(+) Calculated value.
(y) Heat loss figure calculated based on measured surface temperatures. Indicative only

Direct Solar Cylinders

DIMENSIONS
Model Height Diameter T&P Valve Solar Coil return Solar Coil flow Immersion 1 Immersion 2 Thermostat
ECSd175ST-580 1280 580 1050 190 525 630 895 330
ESCd210ST-580 1505 580 1275 190 525 724 1117 330
ECSd250ST-580 1780 580 1550 190 525 790 1350 330
ECSd300ST-580 2080 580 1850 190 525 880 1620 330

Measurements in mm, made from the bottom of the cylinder to the centre of the component

PERFORMANCE
Model Capacity (l) Aux heated volume(l) Solar volume(l) Weight empty (kg) Weight full (kg) Solar Coil size (kW) Solar Coil surface area (m2) Number of immersions Aux reheat time (mins) Reheat (mins) Heat loss in 24 hrs (kW/24hrs)
ECSd175ST-580 175 100(*) 75(*) 34 210(+) 24(*) 1.1 2 101(*) 21(*) 12
ECSd210ST-580 210 125(**) 85(**) 39 252(+) 21(**) 1.1 2 126(**) 24(**) 12
ECSd250ST-580 250 160(**) 90(**) 44(+) 300(+) 19(**) 1.1 2 191(**) 38(**) 12
ECSd300ST-580 300 194(*) 105(*) 50 360(+) 18(*) 1.1 2 208(*) 47(*) 12

(*) Measured in accordance with EN12897-2006 at 80°C flow temperature and 0.25 l/s fl ow rate or operation of immersion heater.
(**) Calculated - based on measurements made in accordance with EN12897 at 80°C fl ow temperature and 0.25 l/s flow rate or operation of immersion heater.
(+) Calculated value.
(y) Heat loss figure calculated based on measured surface temperatures. Indicative only

Name and Registered Office: Dimplex - a division of the GDC Group, Millbrook House, Grange Drive, Hedge End, Southampton, Hants, SO30 2DF, United Kingdom.
Company No.1313016 EEE Producer Registration Number WEE/GE0057TS
WEEE Distributor Take Back Scheme - Registration ID: 6131
This is an official website of GDC Group Limited. The GDC Group manages the Dimplex brand.
Neither the GDC Group nor Dimplex are associated with any other website containing the Dimplex brand name