WATER HEATING - UNVENTED
instantaneous - DE range
Electrical
Supply – 380-415V 3-phase. The unit must be connected to an all-pole isolation switch with a minimum gap of 3mm.
Water Supply and Fittings
Supplied from cold mains water supply only – max 20°C. Standard UK water fittings may be connected to the outlet providing they exceed the minimum flow rates.

Technical Specification
| DEH Models | 1802 | 2102 | 2402 |
|---|---|---|---|
| Rated Power | 18kW | 21kW | 24kW |
| Rated Voltage | 400V 3-Phase | 400V 3-Phase | 400V 3-Phase |
| Economy setting 1st stage 2nd stage |
6kW 12kW |
7kW 14kW |
8kW 16kW |
| High setting II 1st stage 2nd stage |
9kW 18kW |
10.5kW 21kW |
12kW 24kW |
| Switch-on point 1st stage 2nd stage |
4.0 l/min 5.0 l/min |
4.5 l/min 5.8 l/min |
5.0 l/min 6.6 l/min |
| Mixed water at rated power (supply temperature 12ºC) Approx. 38ºC Approx. 50ºC |
9.9 l/min 6.8 l/min |
11.6 l/min 7.9 l/min |
13.2 l/min 9.1 l/min |
| Minimum flow pressure of appliance* With flow limiter Without flow limiter |
0.07 MPa (0.7bar) 0.04 MPa (0.4bar) |
0.08 MPa (0.8bar) 0.05 MPa (0.5bar) |
0.09 MPa (0.9bar) 0.06 MPa (0.6bar) |
| Operative rangein waters of specific resistance at 15ºC | 1300cm | 1300cm | 1300cm |
| Rated pressure | 1 MPa (10bar) | 1 MPa (10bar) | 1 MPa (10bar) |
| Maximum permissible supply temperature | 20ºC | 20ºC | 20ºC |
*Plus any pressure loss at the tap mixer

| DEE Models | 1802 | 2102 | 2402 |
|---|---|---|---|
| Rated Power | 18kW | 21kW | 24kW |
| Rated Voltage | 400V 3-Phase | 400V 3-Phase | 400V 3-Phase |
| Warm water quantity at Rated Power for temperature Increases of 12°C to 38°C |
9.9 l/min 5.4 l/min |
11.6 l/min 6.3 l/min |
13.2 l/min 7.2 l/min |
| Switch-on quantity | 2.6 l/min | 2.6 l/min | 2.6 l/min |
| Switch-on flow pressure* | 0.025 MPa (0.25bar) | 0.025 MPa (0.25bar) | 0.025 MPa (0.25bar) |
| Flow pressure (at rated power & 60°C)* With flow limiter Without flow limiter |
0.028 MPa (0.28bar) 0.013 MPa (0.13bar) |
0.035 MPa (0.35bar) 0.020 MPa (0.20bar) |
0.048 MPa (0.48bar) 0.026 MPa (0.26bar) |
| Operative range in waters of specific electric resistance at 15°C | 1300cm | 1300cm | 1300cm |
| Rated pressure | 1 MPa (10bar) | 1 MPa (10bar) | 1 MPa (10bar) |
| Maximum permissible supply temperature | 20ºC | 20ºC | 20ºC |
| Maximum mains impedance at connection site | - | - | ≤ 0.41 Ω |
Name and Registered Office: Dimplex (UK) Limited, Millbrook House,
Grange Drive, Hedge End, Southampton, Hants, SO30 2DF, United Kingdom.
Company
No.1313016
EEE Producer Registration Number – WEE/GE0057TS