EC-Eau Domestic Cylinders

Specifications

Materials
Inner Cylinder Duplex stainless steel
Outer casing Black HIPS/ABS (from recycled materials)
Inlet/outlet Stainless steel
Coils Corrugated stainless steel
Insulation 60mm PU foam (GWP = 1, ODP = 0)
Max Operating Conditions
Potable water temperature 70oC
Heating water temperature 90oC
Operating pressure 3 bar
Cold Water Supply
Minimum dynamic pressure 1.5 bar
Maximum pressure 12 bar
Minimum flow rate 15l/min
Connections
Cold water inlet 22mm stainless steel
Hot water outlet 22mm stainless steel
Coil flow / return  22mm / 28mm stainless steel
Sensor Surface mounted
T&P valve 0.5 inch F BSP
Immersion heater 1.75 inch F BSP
Safety Components
Pressure reducing valve and strainer 3 bar
Expansion relief valve 6 bar
T&P valve 7 bar / 90oC
Factory pressure tests 12 bar
Expansion external
Guarantee
Inner cylinder 25 years
Immersion heaters 2 years (excluding the effects of limescale)
Other components (excluding expansion vessel membrane) 2 years


Indirect Cylinders

DIMENSIONS
ModelHeightDiameterT&P valveCoil ReturnCoil FlowThermostatImmersion Weight empty (kg) Weight packaged (kg)
ECSi100-580 810 580 580 190 325 430 208 23 33
ECSi125-580 960 580 730 190 325 430 208 25 36
ECSi150-580 1130 580 900 190 325 430 208 29 40
ECSi175-580 1280 580 1050 190 405 430 208 32 44
ECSi210-580 1504 580 1275 190 405 430 208 36 49
ECSi250-580 1780 580 1550 190 405 430 208 42 55
ECSi300-580 2080 580 1850 190 405 430 208 47 51

Measurements in mm, made from the bottom of the cylinder to the centre of the component.

PERFORMANCE
ModelCapacity (litres)Primary hot water capacity (litres)
Coil size (kW) Coil surface area (m2) Expansion vessel (L) Number of immersions Reheat (mins) Heat loss in 24 hrs (kW/24hr)
ECSi100-580 100
95(*) 14(*) 0.5 12 1 22(*) 0.9
ECSi125-580 125 103(+) 13(*) 0.5 12 1 25(*) 0.95
ECSi150-580 150 134(+) 12(*) 0.5 12 1 33(*) 1.10
ECSi175-580 175 155(+) 18(*) 0.8 19 1 27(*) 1.12
ECSi210-580 210 185(+) 19(*) 0.8 19 1 31(*) 1.41
ECSi250-580 250 225(+) 18(*) 0.8 24 1 40(*) 1.51
ECSi300-580 300 274(*) 18(*) 0.8 24 1 49(*) 1.96

(*) Determined in accordance with EN12897-2006


Direct Cylinders

DIMENSIONS
ModelHeightDiameterT&P ValveImmersion 1Immersion 2 Weight empty (kg) Weight packaged (kg)
ECSd100-580 810 580 580 208 - 20 30
ECSd125-580 960 580 730 208 570 23 33
ECSd150-580 1130 580 900 208 650 26 37
ECSd175-580 1280 580 1050 208 750 29 39
ECSd210-580 1504 580 1275 208 820 33 44
ECSd250-580 1780 580 1550 208 1265 39 52
ECSd300-580 2080 580 1850 208 1495 46 50

Measurements in mm, made from the bottom of the cylinder to the centre of the component.

PERFORMANCE
ModelCapacity (litres)Primary hot water capacity (litres) Number of immersions Expansion vessel (litres) Reheat (mins) Heat loss in 24 hrs (kW/24hr)
ECSd100-580 100 83(*) 1 12 88(*) 0.75
ECSd125-580 125 96(*) 2 12 122(*) 0.95
ECSd150-580 150 124(*) 2 12 150(*) 1.10
ECSd175-580 175 149(*) 2 19 199(*) 1.12
ECSd210-580 210 182(*) 2 19 218(*) 1.41
ECSd250-580 250 232(*) 2 24 284(*) 1.51
ECSd300-580 300 260(*) 2 24 313(*) 1.96

(*) Determined in accordance with EN12897-2006

Name and Registered Office: Dimplex - a division of the GDC Group, Millbrook House, Grange Drive, Hedge End, Southampton, Hants, SO30 2DF, United Kingdom.
Company No.1313016 EEE Producer Registration Number WEE/GE0057TS
WEEE Distributor Take Back Scheme - Registration ID: 6131
This is an official website of GDC Group Limited. The GDC Group manages the Dimplex brand.
Neither the GDC Group nor Dimplex are associated with any other website containing the Dimplex brand name